Marvell® Fibre Channel HBAs are getting a promotion and here is the announcement email -
“I am pleased to announce the promotion of “Mr. QLogic® Fibre Channel” to Senior Transport Officer, Storage Connectivity at Enterprise Datacenters Inc. Mr. QLogic has been an excellent partner and instrumental in optimizing mission critical enterprise application access to external storage over the past 20 years. When Mr. QLogic first arrived at Enterprise Datacenters, block storage was in a disarray and efficiently scaling out performance seemed like an unsurmountable challenge. Mr. QLogic quickly established himself as a go-to leader and trusted partner for enabling low latency access to external storage across disk and flash. Mr. QLogic successfully collaborated with other industry leaders like Brocade and Mr. Cisco MDS to lay the groundwork for a broad set of innovative technologies under the StorFusion™ umbrella. In his new role, Mr. QLogic will further extend the value of StorFusion by bringing awareness of Storage Area Network (SAN) congestion into the server, while taking decisive action to prevent bottlenecks that may degrade mission critical enterprise application performance.
この相応の昇格についてQLogicを祝福してください。”
大きなプロモーションの直後に現実が始まり、誰もがあなたが彼らのために何をしようとしているのか、そしてあなたがあなたの新しい役割にどのように付加価値を与えるのかを尋ねます。あなたは期待に応えますか?
この3部構成のブログで(事実上)一緒に旅をして、QLogic氏がどのように貢献しているかを見てみましょう!
第1部: 異機種SANとフラッシュは新たな課題をもたらします
急速なデジタル化の時代、在宅勤務、モビリティ、データの爆発的な増加の中で、ますます多くの組織が、ビジネスの維持と成長のために堅牢なデジタルインフラストラクチャに依存しています。ホストされるビジネスクリティカルなアプリケーションは、大容量で予測可能な方法で実行する必要があります。ファイバーチャネルは、引き続きサーバーアプリケーションとストレージアレイデータの間で選択される接続です。 FC SANは輻輳(ふくそう)のない状態を維持する必要があります。そうすることで、ワークロードをピーク時に実行したり、アプリケーションが停止したりパフォーマンスが低下したりしてビジネスの中断を招く危険性があります。
ファイバーチャネルは、バッファー間クレジットを持つ専用ネットワークに実装されるため、超信頼性で知られています。現実のパラレルについては、目的地の保証された駐車スポットを考えて、私道を出る前にそこにあることを知ってください。 これは、2つの直接接続されたデバイス間でうまく機能し、最近までFC SANの輻輳は一般的に個別の問題でした。ただし、SANの輻輳は、次の理由でデータセンターのより多くの場所で発生するより深刻な問題になる可能性があります。
Heterogenous SAN Speeds: While datacenters have seen widespread deployment of 16GFC and 32GFC, 4/8GFC still remain part of the fabric. Servers and Storage FC ports operating at mismatched speeds tend to congest the links between them.
CapEx and OpEx Pressure: Amidst the global pandemic, businesses are under unprecedented pressure to optimize OpEx and increase their bottom lines. More applications/VMs are being hosted on the same servers increasing stress onto existing SANs causing previously balanced SANs to be prone to congestion.
Flash Storage: FC SANs are no longer limited in performance due to spinning media. With the advent of NVMe and FC-NVMe, SANs are being pushed to their limits and existing links (4/8GFC) may not be able to sustain AFA bandwidth, creating oversubscription scenarios that lead to congestion and congestion spreading.
Data Explosion: Datasets and databases are growing in scale and so are the Fibre Channel SANs that support these applications. Scale out SAN architectures, more ports and end points in a domain, mean that a singular congestion event can spread to and impact a wide set of applications and services.
FC SANs are lossless networks and all frames sent must be acknowledged by the receiver. The sender (e.g. a Storage Array) will stop sending frames if these acknowledgments are not received. Simply put, the inability of a receiver (e.g. FC HBA) to accept frames at the expected rate results in congestion. Congestion can occur due to misbehaving end devices, physical errors or oversubscription. Oversubscription due to the reasons outline above is typically the main culprit.
Introducing the “Aware and Decisive” FC HBAs
マーベルのQLogicファイバーチャネルHBA(別名Mr.QLogic)とその StorFusion のエンドツーエンドのオーケストレーションおよび管理機能のセットは、SANファブリックのパフォーマンス条件を「認識」し、可能なアクションの観点から「決定的」であるソリューションを構築するために拡張されています 輻輳のような、ファブリックを低下させてアプリケーションのパフォーマンスを低下させる可能性のある状態を防止および軽減するために必要です。
マーベル・QLogicユニバーサルSAN輻輳緩和(USCM)テクノロジーは独立して動作し、BrocadeおよびCisco FCファブリックと連携して、輻輳の検出、通知、および回避を可能にすることにより、SANの輻輳を緩和します。QLogicの輻輳「認識」機能とは、輻輳の兆候を通知されるか、もしくは自動的に検出できることを意味します。次にQLogicの「決定的」アクション機能は、トラフィックをより最適化されたパスに切り替えるか、低速デバイスを優先度の低い仮想チャネルに隔離することにより、輻輳を防止または解決することを目的としています。
Available immediately, QLogic Enhanced 16GFC (2690 Series) and Enhanced 32GFC (2770 Series) Adapters have the ability to deliver a wide range of these SAN Congestion Management capabilities.
第2部と第3部のプレビュー
QLogic氏がここで問題を解決していて、輻輳からFC SANを救うための正しいビジョン、動機、専門知識を持っていると思われる場合は、続編に戻ってください。
In Part 2, I will talk about the underlying industry standards-based technology called “Fabric Performance Notification” (FPINs) that form the heart of the QLogic USCM solution.
第3部では、実際のテクノロジーとMarvell QLogicソリューションの独自性について説明します。これは、BrocadeとCisco SANファブリックの両方の輻輳管理を実現できるためです。
Tags: 16GFC, 32GFC, All flash array, FC-NVMe, FC-NVMe 2, Fibre Channel, NVMe, NVMe over Fibre Channel, NVMe over RoCE, NVMe over TCP, Sequence Level Error Recovery, server connectivity, SLER, storage connectivity